Implementation Assistance
University of Pittsburgh Medical Center
Project Description: IES performed central plant functional performance testing and analysis to develop energy conservation measures. IES then assisted UPMC with developing detailed Contractor Statements of Work and soliciting prices from Mechanical equipment vendors and contractors, electricians, and controls integration contractors to perform the work, then managed the installation of the measures.
Project Description: IES performed central plant functional performance testing and analysis to develop energy conservation measures. IES then assisted UPMC with developing detailed Contractor Statements of Work and soliciting prices from Mechanical equipment vendors and contractors, electricians, and controls integration contractors to perform the work, then managed the installation of the measures.
Seagate’s Disk Drive R&D Facility, Longmont , CO
Project Description: Mechanical system design-build of a 460,000 sq. ft. R&D facility including 12,000 sq. ft. of Class 10 cleanroom, offices, laboratories and an employee fitness center. Services included piping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Project Description: Mechanical system design-build of a 460,000 sq. ft. R&D facility including 12,000 sq. ft. of Class 10 cleanroom, offices, laboratories and an employee fitness center. Services included piping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Maxtor’s Disk Drive R&D Facility, Longmont , CO
Project Description: Mechanical system design-build of an R&D facility including Class 10 clean rooms, offices and laboratories. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Project Description: Mechanical system design-build of an R&D facility including Class 10 clean rooms, offices and laboratories. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Research Electro Optics, Boulder , CO
Projet Description: Mechanical system design-build of an R&D facility including Class 100 clean rooms, offices and laboratories. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Projet Description: Mechanical system design-build of an R&D facility including Class 100 clean rooms, offices and laboratories. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; and review of documents from all trades for coordination purposes.
Advanced Thin Films, Boulder , CO
Project Description: Mechanical system design and commissioning of a 10,000 sq. ft., Class 10,000 clean room. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; review of documents from all trades for coordination purposes, and commissioning of all systems.
Project Description: Mechanical system design and commissioning of a 10,000 sq. ft., Class 10,000 clean room. Services included iping, duct, load, and sizing calculations for systems and equipment; drafting/CAD redlines; permit and construction documents; review of documents from all trades for coordination purposes, and commissioning of all systems.